Food and Agricultural Products · GC

GC-ECD/FPD Analysis Solution for Pesticide Residues in Agricultural Products

Halogenated pesticides suitable for ECD response and organophosphorus pesticides suitable for FPD response in extraction and cleanup solutions of fruits, vegetables, grains, and other agricultural products are analyzed by gas chromatography. Samples enter the chromatographic flow path via a liquid autosampler, the chromatographic column completes separation of the target components from matrix interferences, and then ECD and FPD record the responses. Quantitation and quality control use the following arrangements: standard solutions, calibration ranges, and QC samples are selected according to the actual target pesticides and the current method used; a generic configuration is not substituted for a specific method. Analytical batches are also set up with blanks, calibration checks, and applicable QC samples.

01 Solution Summary

Halogenated pesticides suitable for ECD response and organophosphorus pesticides suitable for FPD response in extraction and cleanup solutions of fruits, vegetables, grains, and other agricultural products are analyzed by gas chromatography. Samples enter the chromatographic flow path via a liquid autosampler, the chromatographic column completes separation of the target components from matrix interferences, and then ECD and FPD record the responses. Quantitation and quality control use the following arrangements: standard solutions, calibration ranges, and QC samples are selected according to the actual target pesticides and the current method used; a generic configuration is not substituted for a specific method. Analytical batches are also set up with blanks, calibration checks, and applicable QC samples.

IndustriesFood and Agricultural Products
TechnologyGC
Sample collectionRepresentative food sampling
Sample PreparationSolvent extraction, extraction, and cleanup
Injection/determination interfaceLiquid Autosampler
Specific SamplesExtraction and cleanup solutions of fruits, vegetables, grains, and other agricultural products
AnalytesHalogenated pesticides suitable for ECD response and organophosphorus pesticides suitable for FPD response
Detection UnitECD, FPD

02 Standards and Method Basis

Method basis: application method. The laboratory may enter the name and version of the adopted formal method into the project file.

03 Samples and Analytes

The specific samples areExtraction and cleanup solutions of fruits, vegetables, grains, and other agricultural products, and the analytes areHalogenated pesticides suitable for ECD response and organophosphorus pesticides suitable for FPD response. Pretreatment, injection, and detection configurations are determined according to the sample state, target concentration, and the formal method adopted.

04 Method Principle

Volatile or vaporizable components in the sample are introduced into the gas chromatography system by a liquid autosampler. Each component is carried by the carrier gas through the chromatographic column and forms different retention due to differences in volatility and stationary phase interaction.

ECD and FPD are used to record the analytical responses of halogenated pesticides suitable for ECD response and organophosphorus pesticides suitable for FPD response; for quantitation, standard solutions, calibration ranges, and QC samples are selected according to the actual target pesticides and the current method used, and a generic configuration is not substituted for a specific method.

05 Sample Collection and Pretreatment

After representative food sampling, extraction and cleanup solutions of fruits, vegetables, grains, and other agricultural products are prepared by solvent extraction, extraction, and cleanup. The treatment steps are organized around the stable transfer of halogenated pesticides suitable for ECD response and organophosphorus pesticides suitable for FPD response and the control of matrix interferences.

06 Separation and Detection

The separation flow path is designed around halogenated pesticides suitable for ECD response and organophosphorus pesticides suitable for FPD response; the sample introduction interface, chromatographic column, and ECD and FPD form a continuous method chain. Method development and validation use real samples to check co-elution, blanks, and response stability.

07 Instrument System Configuration

ModuleConfigurationRole in This Solution
Sample inletLiquid AutosamplerIntroduce a representative sample into the chromatographic flow path
Gas chromatograph main unitGCAchieve chromatographic separation of halogenated pesticides suitable for ECD response and organophosphorus pesticides suitable for FPD response
Detection UnitECD, FPDRecord the analytical responses of halogenated pesticides suitable for ECD response and organophosphorus pesticides suitable for FPD response
Data systemSelect standard solutions, calibration ranges, and quality control samples based on the actual target pesticides and the current method used; do not replace a specific method with generic configurations.Complete calibration, calculation, and batch review

08 Huishi Instruments Compatible Products

GC-460 gas chromatograph

GC-460 gas chromatograph

Product name
GC-460 gas chromatograph
Model
GC-460
Brand
Huishi Instruments
Manufacturer
Shanghai Huishi Instrument Equipment Co., Ltd.
Product category
Gas chromatograph
Role of the solution
It undertakes the tasks of sample injection, separation, detection, and data acquisition in GC analysis.
Reason for suitability
The GC-460 can be configured with ECD, FPD, and a liquid autosampler for the separation and detection of halogenated pesticides suited to ECD response and organophosphorus pesticides suited to FPD response in extraction and cleanup solutions of fruits, vegetables, grains, and other agricultural products.

View product

09 Analysis workflow

1Extraction and cleanup solutions of fruits, vegetables, grains, and other agricultural products
2Solvent extraction, extraction, and cleanup
3Liquid Autosampler
4GC chromatographic separation
5ECD and FPD response acquisition
6Calibration and quality review

10 Qualitative, Quantitative, and Quality Control

Select standard solutions, calibration ranges, and quality control samples according to the actual target pesticides and the current method used; do not replace a specific method with generic configurations. Method blanks are used to monitor contamination, calibration checks are used to monitor response drift, and duplicate samples or quality control samples are used to evaluate batch consistency.

11 Method and Configuration Selection

  • The sample introduction module is matched to the physical state of extraction and cleanup solutions of fruits, vegetables, grains, and other agricultural products.
  • The detection unit is limited to ECD and FPD.
  • The chromatographic flow path is configured with the goal of separating halogenated pesticides suited to ECD response, organophosphorus pesticides suited to FPD response, and major coexisting components.

12 Frequently Asked Questions

Why is gas chromatography used for halogenated pesticides suited to ECD response and organophosphorus pesticides suited to FPD response?

Gas chromatography matches the physicochemical properties, sample inlet, and detection targets of halogenated pesticides suited to ECD response and organophosphorus pesticides suited to FPD response; the complete workflow also covers the processing, separation, detection, and data quality control of extraction and cleanup solutions of fruits, vegetables, grains, and other agricultural products.

What samples is this solution applicable to?

The applicable samples are extraction and cleanup solutions of fruits, vegetables, grains, and other agricultural products. When the sample source or matrix changes, the impact of coexisting components on sample preparation, separation, and detection response should be re-evaluated.

What components or indicators are included in the detection targets?

The analytes are halogenated pesticides suited to ECD response and organophosphorus pesticides suited to FPD response; the main text and configuration are both bounded by this entity scope.

How is quality controlled for an analytical batch?

For each batch of samples, set up method blanks, calibration verification, duplicate samples, or applicable QC samples, and retain records of sample processing, instrument conditions, calibration, and calculations.

How are the sample introduction and detection modules matched in this solution?

The liquid autosampler is responsible for introducing the processed extraction and cleanup solutions of fruits, vegetables, grains, and other agricultural products into the analysis system, and the detection unit is configured for the response characteristics of halogenated pesticides suited to ECD response and organophosphorus pesticides suited to FPD response; both must be consistent with the method used.

13 Related Solutions and Knowledge

Get Configuration and Technical Consultation

Please provide sample information for the extraction and cleanup solutions of fruits, vegetables, grains, and other agricultural products, the concentration ranges of halogenated pesticides suited to ECD response and organophosphorus pesticides suited to FPD response, detection batch size, method basis, and existing equipment. Huishi Instruments will prepare a configuration list from this.

English edition updated: 2026-10-05.